2023年10月31日–11月02日
英国 (Stafford)
英語
Cprs19en
Test Universe, ADMO 延时分级时限

Automated Power System Protection Testing

2023年10月31日–11月02日
英国 (Stafford)
英語
Cprs19en
Test Universe, ADMO 延时分级时限

主要特点

You will learn how to efficiently test overcurrent, distance and transformer differential relays with the OMICRON Test Universe. Become familiar with the test procedures in theoretical and hands-on sessions and get to know the benefits of automated testing and reusable test templates.

学习目标

  • Get familiar with the CMC test set and the Test Universe software for testing overcurrent protection relays
  • Get to know important safety aspects for test preparation and execution
  • Refresh your technical knowledge of overcurrent, distance and differential protection
  • Be able to choose the appropriate software modules for testing distance and transformer differential relays
  • Become more efficient in testing by creating and expanding reusable test plans
  • Know the OMICRON support options including technical support, knowledge library and the worldwide community
  • Get to know the full range of OMICRON solutions for protection testing
  •  

内容

  • Power system protection principles and typical substation topologies
  • Overview of protection testing basics
  • Introduction to the OMICRON Control Center (OCC) and relevant test modules
  • Modelling of the relay characteristics in the Test Object for subsequent testing
  • Test setup and configuration options for the CMC test set
  • Quick current and voltage output for easy wiring tests
  • Fundamentals of non-directional overcurrent protection functions
  • Creating a reusable test plan (OCC file) for testing non-directional overcurrent relays
  • Hands-on testing of non-directional overcurrent protection
  • Fundamentals of distance, ground fault and transformer differential protection functions
  • Creating a reusable test plan for testing distance relays
  • Creating a reusable test plan for testing transformer differential relays
  • Testing ground fault protection with RelaySimTest using realistic network simulation
  • Hands-on testing of distance and transformer differential relays as well as ground fault protection function
  •  

时间表

Day 1: 08:45 a.m. - 05:30 p.m.

Day 2: 09:00 a.m. - 05:30 p.m.

Day 3: 09:00 a.m. - 04:00 p.m.

资料

You will receive a personal email with all course information such as agenda and route directions shortly before the training course.

You can select your desired hotel from our hotel recommendations in UK Training Center83 kB and book it directly according to your preferences.

参加者

Technical staff from utilities or companies working mainly in commissioning or maintenance testing

必备知识

Basic knowledge of power system protection

产品

Test Universe: QuickCMC, Ramping, Pulse Ramping, State Sequencer, Overcurrent, Advanced Distance, Advanced Differential
OMICRON Control Center
RelaySimTest, CMControl, ADMO
CMC-Family

GBP 2,040
以每人计, (不含税)
seats available
请注册

„所有的培训主题都很有意思并且培训师很好的进行了演示和说明。“

学生心声
高效的培训方法
深入讨论
专业的培训材料
seats available
请注册
10 其他培训日期
2023年07月11–13日
印度 (New Delhi)
英語
2023年06月27–29日
英国 (Stafford)
英語
2023年09月26–28日
英国 (Stafford)
英語
2023年10月10–12日
英国 (Stafford)
英語
2023年11月28–30日
英国 (Stafford)
英語
2023年12月06–08日
印度 (New Delhi)
英語
2023年10月03–05日
芬兰 (Tampere)
英語
2023年11月07–09日
英国 (Stafford)
英語
2023年10月10–12日
瑞典 (Solna)
英語
2024年04月09–11日
冰岛 (Reykjavík)
英語
You are using an outdated browser version.