2025年01月07–09日
芬兰 (Vantaa)
英語
Cprs19en
Test Universe

Automated Power System Protection Testing

2025年01月07–09日
芬兰 (Vantaa)
英語
Cprs19en
Test Universe

主要特点

You will learn how to efficiently test overcurrent, distance and transformer differential relays with the OMICRON Test Universe. Become familiar with the test procedures in theoretical and hands-on sessions and get to know the benefits of automated testing and reusable test templates. 

学习目标

  • Get familiar with the CMC test set and the Test Universe software for testing overcurrent protection relays
  • Get to know important safety aspects for test preparation and execution
  • Refresh your technical knowledge of overcurrent, distance and differential protection
  • Be able to choose the appropriate software modules for testing distance and transformer differential relays
  • Become more efficient in testing by creating and expanding reusable test plans
  • Know the OMICRON support options including technical support, knowledge library and the worldwide community
  • Get to know the full range of OMICRON solutions for protection testing
  •  

内容

  • Power system protection principles and typical substation topologies
  • Overview of protection testing basics
  • Introduction to the OMICRON Control Center (OCC) and relevant test modules
  • Modelling of the relay characteristics in the Test Object for subsequent testing
  • Test setup and configuration options for the CMC test set
  • Quick current and voltage output for easy wiring tests
  • Fundamentals of non-directional overcurrent protection functions
  • Creating a reusable test plan (OCC file) for testing non-directional overcurrent relays
  • Hands-on testing of non-directional overcurrent protection
  • Fundamentals of distance, ground fault and transformer differential protection functions
  • Creating a reusable test plan for testing distance relays
  • Creating a reusable test plan for testing transformer differential relays
  • Testing ground fault protection with RelaySimTest using realistic network simulation
  • Hands-on testing of distance and transformer differential relays as well as ground fault protection function
  •  

时间

3 days

时间表

Tuesday 10.00 - 18.00
Wednesday 08.30 - 17:15
Thursday 08.30 - 15.00

资料

Training Location:

Scandic Helsinki Aviacongress

Robert Huberin tie 4

Vantaa 01510 Finland

Website of Hotel:

Scandic Helsinki Aviacongress - Guest Reservations 

Please book your own accomodation directly with the hotel

Training language: English

Pricing: The price excl. VAT and includes break service, coffee and lunch all three days.

Payment terms: Invoice will be sent 30 days before the course starts (due 30 days).

Cancellation Policy:
Less than 4 weeks’ notice; 75% of the fee will be charged, if you do not send another person.
Less than 2 weeks’ notice; 100% of the fee will be charged, if you do not send another person

参加者

Technical staff from utilities or companies working mainly in commissioning or maintenance testing

必备知识

Basic knowledge of power system protection

产品

Test Universe: QuickCMC, Ramping, Pulse Ramping, State Sequencer, Overcurrent, Advanced Distance, Advanced Differential
OMICRON Control Center
RelaySimTest, CMControl, ADMO
CMC-Family

EUR 2,800
以每人计, (不含税)
Seats available
请注册

„真令人吃惊,通过培训师的演示的实例,我居然非常容易的理解了这些内容!“

学生心声
应用知识
高效的培训方法
专业的培训材料
Seats available
请注册
16 其他培训日期
2025年02月04–06日
印度 (New Delhi)
英語
2024年11月19–21日
瑞典 (Solna)
英語
2025年12月09–11日
奥地利 (Klaus)
英語
2024年11月26–28日
奥地利 (Klaus)
英語
2024年11月12–14日
芬兰 (Hämeenlinna)
英語
2025年01月14–16日
英国 (Stafford)
英語
2025年02月25–27日
英国 (Stafford)
英語
2025年03月11–13日
英国 (Stafford)
英語
2025年03月25–27日
英国 (Stafford)
英語
2025年04月29日–05月01日
英国 (Stafford)
英語
2025年06月03–05日
英国 (Stafford)
英語
2025年06月17–19日
英国 (Stafford)
英語
2025年09月16–18日
英国 (Stafford)
英語
2025年09月29日–10月01日
英国 (Stafford)
英語
2025年10月14–16日
英国 (Stafford)
英語
2025年11月11–13日
英国 (Stafford)
英語
You are using an outdated browser version.
Please upgrade your browser or use another browser to view this page correctly.
×