2024年12月10–12日
印度 (New Delhi)
英語
Cprs19en
Test Universe

Automated Power System Protection Testing

2024年12月10–12日
印度 (New Delhi)
英語
Cprs19en
Test Universe

主要特点

You will learn how to efficiently test overcurrent, distance and transformer differential relays with the OMICRON Test Universe. Become familiar with the test procedures in theoretical and hands-on sessions and get to know the benefits of automated testing and reusable test templates.

学习目标

  • Get familiar with the CMC test set and the Test Universe software for testing overcurrent protection relays
  • Get to know important safety aspects for test preparation and execution
  • Refresh your technical knowledge of overcurrent, distance and differential protection
  • Be able to choose the appropriate software modules for testing distance and transformer differential relays
  • Become more efficient in testing by creating and expanding reusable test plans
  • Know the OMICRON support options including technical support, knowledge library and the worldwide community
  • Get to know the full range of OMICRON solutions for protection testing
  •  

内容

  • Power system protection principles and typical substation topologies
  • Overview of protection testing basics
  • Introduction to the OMICRON Control Center (OCC) and relevant test modules
  • Modelling of the relay characteristics in the Test Object for subsequent testing
  • Test setup and configuration options for the CMC test set
  • Quick current and voltage output for easy wiring tests
  • Fundamentals of non-directional overcurrent protection functions
  • Creating a reusable test plan (OCC file) for testing non-directional overcurrent relays
  • Hands-on testing of non-directional overcurrent protection
  • Fundamentals of distance, ground fault and transformer differential protection functions
  • Creating a reusable test plan for testing distance relays
  • Creating a reusable test plan for testing transformer differential relays
  • Testing ground fault protection with RelaySimTest using realistic network simulation
  • Hands-on testing of distance and transformer differential relays as well as ground fault protection function
  •  

时间

3 Days

资料

You will receive a personal email with all course information such as agenda and route directions shortly before the training course.  

For participants outside India, the course fee of 375 EUR is applicable.

INR price for this training excludes 18% GST.

*All training dates are scheduled depending on COVID-19 restrictions at the time of the training taking place and may be canceled at any time leading up to the training course.  OMICRON would highly recommend booking any hotels/transport etc which are fully flexible and can be canceled/amended at short notice.

参加者

Technical staff from utilities or companies working mainly in commissioning or maintenance testing

必备知识

Basic knowledge of power system protection

产品

Test Universe: QuickCMC, Ramping, Pulse Ramping, State Sequencer, Overcurrent, Advanced Distance, Advanced Differential
OMICRON Control Center
RelaySimTest, CMControl, ADMO
CMC-Family

INR 24,000
以每人计, (不含税)
请注册

„培训师的确知道他们在说什么,真棒!“

学生心声
应用知识
深入讨论
专业的培训材料
10 其他培训日期
2024年05月14–16日
瑞典 (Solna)
英語
2024年11月19–21日
瑞典 (Solna)
英語
2024年11月26–28日
奥地利 (Klaus)
英語
2024年10月29–31日
挪威 (Oslo)
英語
2024年11月11–13日
芬兰 (Hämeenlinna)
英語
2025年01月14–16日
英国 (Stafford)
英語
2025年02月25–27日
英国 (Stafford)
英語
2025年03月11–13日
英国 (Stafford)
英語
2025年03月25–27日
英国 (Stafford)
英語
2025年04月29日–05月01日
英国 (Stafford)
英語
You are using an outdated browser version.
Please upgrade your browser or use another browser to view this page correctly.
×